Full laboratory Explore
Linked pressure–volume loops, traces, circulation map and measurements; every control, intervention and drug; a baseline and comparison snapshots.
Leaves out: A defined virtual patient, not a model of any individual.
One closed-loop model drives every view. 25 lessons (25 of 25 foundation topics), 30 cases, 9 conditions and 38 scenarios, with what each leaves out stated beside it.
A lumped-parameter model of the whole circulation: four heart chambers with time-varying elastance, systemic and pulmonary arteries and veins, valves that open and close with pressure, the pericardium and pleural pressure, and conserved blood volume. It is solved in your browser, and the pressure–volume loops, traces, circulation map and every number come from the same simulated beat.
Linked pressure–volume loops, traces, circulation map and measurements; every control, intervention and drug; a baseline and comparison snapshots.
Leaves out: A defined virtual patient, not a model of any individual.
LV and RV loops, end-diastolic and end-systolic points, ESPVR/EDPVR lines, stroke work and arterial elastance, overlay or side-by-side comparison.
Leaves out: Ees from a single loop is not identifiable; the model's Ees is a parameter.
Right atrial, RV, PA, wedge, LA, LV and aortic waveforms by recording site, with labels, calipers, measured-signal artifacts and a hide-the-labels quiz.
Leaves out: No real recordings are included; the idealised and measured signals are generated.
ECG timing aid, pressures, volume, flows and valve states with a phase explanation at the cursor.
Leaves out: The ECG is a timing aid, not a modelled electrical signal.
Cardiac function and venous return curves, mean systemic filling pressure, and manoeuvres such as passive leg raise and diuresis.
Leaves out: The venous return line is schematic; the function curve is generated by the model.
Aortic, mitral and tricuspid lesions (acute and chronic), HOCM, tamponade, constriction, restriction, pulmonary hypertension and heart-failure phenotypes.
Leaves out: Pulmonary valve disease and combined lesions are not supported; constriction does not reproduce LV/RV discordance.
Seven shock phenotypes and ten named drugs as qualitative multi-target mappings, with oxygen delivery from a Fick teaching model.
Leaves out: Drug strengths are qualitative, not doses; no organ-level outcomes or drug kinetics.
Spontaneous and positive-pressure breathing, PPV and SVV with caveats; graded exercise, Valsalva and fluid challenge; PVCs, AF and AV dissociation.
Leaves out: No lung-volume effect on PVR; the exercise mapping is illustrative; dyssynchrony is not modelled.
IABP timing, LV pump with suction, VA-ECMO, ECPELLA and ASD/VSD, with native-versus-device flow accounting.
Leaves out: Device curves are placeholders, not manufacturer data; no differential oxygenation; no RV support devices.
Valve relief or repair, drainage and shunt closure, immediately after versus remodelled.
Leaves out: The remodelled state is an authored parameter set; no time course; AV fistula is not supported.
Sequential recordings, artifact settings, reliability judgements before derived values, and output by Fick or thermodilution.
Leaves out: No station-by-station oximetry run for shunts.
Build and present sequences with locked controls and stepwise reveal; classroom projection; share links.
Leaves out: Sequences live in the browser and can be exported; share links hold state in the URL; no server-side snapshots.
Finding Hemo app 0.5.0 · content 0.5.0 · engine fh-closed-loop 0.4.0. Solver: RK4 at 0.2 ms, output at 1 kHz, run in a Web Worker; a state is called settled when three consecutive windows agree on eight summary measures. The scientific model document is docs/science/MODEL.md, the validation report docs/validation/REPORT.md and the milestone history docs/MILESTONES.md in the repository.