Sources & model details

Where the teaching comes from, how far it has been checked, and what the simulation leaves out. These are three different questions, kept apart on purpose.

1. Content review status

Whether people with the right expertise have checked the teaching statements, parameter values and answer keys. At present, 0 of 25 lessons, 0 of 30 cases and 0 of 37 source claims have been expert reviewed. All of it is proposed teaching content; no reviewer approvals are recorded. 37 claims still lack an exact passage locator, which blocks release.

2. Simulation testing status

Whether the equations are solved correctly and behave as stated: volume conservation, step-size convergence, repeatable runs, a normal baseline, and the expected direction of each intervention and phenotype. The core model is recorded as quantitatively tested; the device circuits are proposed (device curves are placeholders, not manufacturer data). Passing these tests does not mean that any lesson, case answer or normal range has been expert reviewed.

3. Limitations

Each lesson, case and topic lists the limitations that matter for it under its own “Sources & model details”. General ones: no real recordings are included; the baroreflex is an optional first-order teaching controller; remodelled states are authored parameter sets, not simulated time courses; oxygen transport is a steady-state teaching model. The full list is in What the simulator covers.

No dangling source references. 37 claims are registered, 37 proposed and 0 source mapped.

Technical detailsversions and model records

App 0.5.0 · content 0.5.0 · model fh-closed-loop 0.4.0.

Model records

MR-fh-closed-loop Benchmarked model Quantitatively tested model fh-closed-loop v0.4.0

Finding Hemo closed-loop lumped-parameter model

Equations
docs/science/MODEL.md
Implementation
src/engine/model.ts, src/engine/simulator.ts, src/engine/valve.ts, src/engine/activation.ts
Licence
Original implementation (project licence). S01/S02 cited as precedent only; no code or parameters copied.
Solver
RK4, dt = 0.2 ms, output 1 kHz; settling = 3 consecutive beats within 0.5% on 8 summary metrics; max 80 beats. Ramped interventions interpolate parameters linearly over N beats.
Error metrics
Volume drift < 1e-9 relative over 100 beats; core stable metrics change < 1% at dt/2.
Calibration
None. Parameters hand-tuned to textbook resting ranges (CL-normal-resting-ranges).
Benchmarks
VF-normal-baseline; tests/science/controlled-changes.test.ts (directional); tests/science/phenotypes.test.ts (qualitative phenotype patterns); tests/science/drugs.test.ts (directional drug effects); tests/science/clamps-oxygen-migration.test.ts; tests/science/observation.test.ts
Excluded physiology
Baroreflex and other reflexes; Ventricular interdependence via septum; Inertance / wave reflection; Afterload- or ischaemia-dependent contractility; Device circuits; Dynamic outflow obstruction; Remodelling and drug kinetics; Regional oxygen extraction (ScvO2)
Reviewer
none — Software, conservation and qualitative pattern tests pass. Not expert reviewed; normal ranges and phenotype parameter sets are proposed teaching values. 0.2.0 adds isolated-physiology clamps (LA, RA, systemic arterial pressure with explicit reservoir accounting), a steady-state Fick oxygen teaching model (no hemodynamic feedback), ramped interventions, and uses the exponential pericardium in the RV-failure, biventricular and PE phenotypes.
MR-mcs-circuits Benchmarked model Proposed model fh-closed-loop v0.4.0

Device circuits: IABP, microaxial pump, VA-ECMO, intracardiac shunts

Equations
docs/science/MODEL.md section 16
Implementation
src/engine/model.ts (devices), src/engine/simulator.ts (IABP scheduler)
Licence
Original implementation. Pressure–flow characteristics are explicit placeholder parameters, not manufacturer data.
Solver
Same RK4 integrator; IABP balloon volume ramps over the transition time; pump flows evaluated at every stage.
Error metrics
Closed-loop volume conserved to floating precision with all circuits active; native + device flow equals mean systemic flow within 2% at steady state.
Calibration
None.
Benchmarks
tests/science/devices.test.ts (conservation, timing errors, head dependence, suction, distension, flow balance)
Excluded physiology
Manufacturer pressure–flow curves (placeholders in use); Haemolysis, cannula resistances, circuit oxygenator physics; Spatial oxygen mixing (differential oxygenation); Right-sided support and durable LVADs
Reviewer
none — Explanatory/teaching device circuits. Device-specific validation against manufacturer data is a release gate and has NOT been done.

Claims

IDClaimSources / passageStatus
CL-normal-resting-rangesTypical resting adult hemodynamics: aortic pressure about 100–140/60–90 mmHg, mean PA pressure 9–18 mmHg, PAWP 4–12 mmHg, RAP 0–6 mmHg, LVEDV 100–160 mL, LVEF 55–70%, cardiac output 4–7 L/min, cardiac index 2.2–4.0 L/min/m², SVR 10–20 Wood units, PVR 0.5–2.0 Wood units.
Healthy resting adults · Supine rest; teaching ranges, not diagnostic cut-offs.
TXT-physiology
TODO: map to specific textbook/guideline tables.
Teaching approximation
Proposed
CL-sv-definitionTotal chamber stroke volume is end-diastolic minus end-systolic volume and includes any regurgitant volume; forward stroke volume is the volume ejected through the outlet valve.
General · Any
TXT-physiology
TODO
Clinical reference
Proposed
CL-forward-flowForward valve flow is the time integral of positive flow through the valve; regurgitant volume is the integral of retrograde flow. In regurgitation, shunts or MCS, forward output must be derived from the appropriate flow signal rather than chamber excursion.
General · Any
TXT-physiology
TODO
Clinical reference
Proposed
CL-ef-not-contractilityEjection fraction is load dependent and is not a measure of contractility; end-systolic elastance (Ees) is the model contractility parameter.
General · Any
TXT-physiology
TODO
Clinical reference
Proposed
CL-co-definitionIn an unsupported, steady circulation without shunts, cardiac output equals forward stroke volume times heart rate; cardiac index is CO divided by body surface area.
General · No shunt, no device
TXT-physiology
TODO
Clinical reference
Proposed
CL-svr-pvrSVR = (MAP − RAP) / systemic flow; PVR = (mPAP − PAWP) / pulmonary flow; in Wood units (mmHg·min/L), multiplied by 80 for dyn·s·cm⁻⁵. Resistance should not be calculated from negligible or invalid flow.
General · Valid flow measurement
S07, TXT-physiology
S07: TODO exact section
Clinical reference
Proposed
CL-pawp-aliasPulmonary artery wedge pressure (PAWP) and pulmonary capillary wedge pressure (PCWP) refer to the same measurement; the mean wedge approximates mean left atrial pressure under stated assumptions.
General · Correct catheter position; no pulmonary venous obstruction
S07
TODO
Clinical reference
Proposed
CL-ea-definitionEffective arterial elastance Ea is end-systolic pressure divided by stroke volume; it is a lumped afterload index, not SVR, and the standard definition assumes an unsupported circulation without major regurgitation.
General · No major regurgitation or device
TXT-physiology
TODO: modern coupling reviews required
Clinical reference
Proposed
CL-ees-identifiabilityA single ordinary PV loop does not identify Ees; estimating it clinically requires a multi-beat loading manoeuvre or single-beat approximations with stated assumptions. In the simulator Ees is a known model parameter.
General · Any
TXT-physiology
TODO
Teaching approximation
Proposed
CL-stroke-workStroke work is the area enclosed by the pressure–volume loop (∮P dV); 1 mmHg·mL = 1.333×10⁻⁴ J.
General · Closed loop (steady beat)
TXT-physiology
TODO
Clinical reference
Proposed
CL-cpoCardiac power output = MAP × CO / 451 (W). No single threshold is a universal treatment target.
General · Any
S08
TODO
Clinical reference
Proposed
CL-papiPAPi = (PA systolic − PA diastolic) / RAP. Interpretation is context dependent.
General · RAP measurable and not near zero
S09
TODO
Clinical reference
Proposed
CL-fluid-stressed-volumeVenous return is driven by the gradient between mean systemic filling pressure and right atrial pressure; mean systemic filling pressure depends on stressed volume and venous compliance. Fluid adds stressed volume; venoconstriction converts unstressed to stressed volume without changing total volume.
General · Closed circulation
TXT-physiology
TODO: Guyton venous-return literature
Clinical reference
Proposed
CL-afterload-ees-shiftWith a pure increase in arterial resistance, end-systolic volume rises along the ESPVR and stroke volume falls; because the arterial compliance fills over several beats, aortic pressure and ESV change little on the first beat and build to a new steady state.
General · No reflexes; constant Ees and preload
TXT-physiology
TODO
Clinical reference
Proposed
CL-starling-fillingIncreasing end-diastolic volume increases stroke volume (Frank–Starling); on an exponential EDPVR the filling-pressure cost rises more steeply as volume increases.
General · Constant contractility and afterload
TXT-physiology
TODO
Clinical reference
Proposed
CL-fick-oxygenArterial oxygen content ≈ 1.34 × Hb × SaO₂; oxygen delivery = CaO₂ × CO × 10; by the Fick principle at steady state VO₂ = CO × (CaO₂ − CvO₂), so mixed venous saturation falls as delivery falls for a fixed consumption. ScvO₂ and SvO₂ are different measurements.
General · Any
S07, TXT-physiology
TODO
Clinical reference
Proposed
CL-hfref-patternSystolic heart failure shows a reduced ejection fraction with a rightward-shifted, enlarged pressure–volume loop and raised filling pressures; chronic eccentric remodelling increases chamber volume and compliance compared with an acute loss of contractility.
General · Any
TXT-physiology
TODO
Clinical reference
Proposed
CL-hfpef-patternHFpEF phenotypes show raised filling pressures with a preserved ejection fraction; passive stiffness (steep EDPVR) and impaired active relaxation are distinct mechanisms with different rate dependence.
General · Any
TXT-physiology
TODO
Clinical reference
Proposed
CL-shock-phenotypesShock phenotypes differ in output, filling pressures and vascular resistance even at similar mean arterial pressure: cardiogenic (low output, high filling pressure, high resistance), hypovolaemic (low output, low filling pressure, high resistance), distributive (normal/high output, low resistance), obstructive (low output with high right-sided pressure) and mixed forms.
General · Any
S08, TXT-physiology
S08: TODO exact section
Clinical reference
Proposed
CL-drug-mechanisms-qualitativeVasoactive and inotropic drugs act on several targets at once (arteriolar tone, venous tone, contractility, rate, relaxation); their hemodynamic effect depends on the phenotype. The simulator maps each named drug to qualitative multi-target effects without doses or kinetics.
General · Any
S08, TXT-physiology
TODO: pharmacology references required per drug
Teaching approximation
Proposed
CL-gradient-definitionsInstantaneous peak, peak-to-peak and mean gradients are different quantities; for a fixed orifice the gradient scales with the square of flow, so low-flow states understate severity and transmitral gradients rise with shorter diastole.
General · Any
S03, S07
TODO
Clinical reference
Proposed
CL-v-waveThe atrial v wave reflects filling against a closed AV valve and depends on atrial compliance and inflow; a large wedge v wave is not a stand-alone MR severity classifier.
General · Any
S07
TODO
Clinical reference
Proposed
CL-transmural-pressureChamber distension depends on transmural pressure (intracavitary minus external); pleural and pericardial pressure make measured filling pressures differ from the distending pressure.
General · Any
TXT-physiology, S06
TODO
Clinical reference
Proposed
CL-hocm-dynamic-obstructionDynamic LVOT obstruction in HCM depends on cavity size, contractility and afterload: it increases with reduced preload, reduced afterload, increased contractility and post-extrasystolic potentiation (Brockenbrough–Braunwald–Morrow sign: post-PVC gradient rises while aortic pulse pressure falls).
General · Any
S04
TODO
Clinical reference
Proposed
CL-pva-energeticsPressure–volume area (stroke work plus potential energy) relates to myocardial oxygen consumption in experimental preparations; the relation is not a clinical measurement and efficiency cannot be read from one loop.
General · Any
TXT-physiology
TODO: Suga ventricular energetics literature
Teaching approximation
Proposed
CL-pericardial-physiologyTamponade raises intrapericardial pressure so that diastolic pressures equalise and inspiratory RV filling occurs at the expense of LV filling (pulsus paradoxus); constriction shields the heart from pleural pressure (dissociation of intrathoracic and intracardiac pressures) and produces discordant respiratory variation of LV and RV systolic pressures, whereas restriction produces concordant variation. Equalised pressures or a dip-and-plateau alone do not establish constriction.
General · Any
S06
TODO
Clinical reference
Proposed
CL-ph-classificationPulmonary hypertension is defined hemodynamically by mPAP, PAWP and PVR thresholds stored in the rule set RS-ph-hemodynamic-classification (2022 ESC/ERS); a hemodynamic classification does not establish aetiology or justify a pulmonary vasodilator.
General · Any
S05
TODO: exact table
Clinical reference
Proposed
CL-ppv-svv-limitsPulse pressure and stroke volume variation predict fluid responsiveness only under controlled ventilation with adequate tidal volume, regular rhythm and no spontaneous effort; they are unreliable with arrhythmia, spontaneous breathing, low tidal volume or RV dysfunction.
General · Any
S08
TODO
Clinical reference
Proposed
CL-baroreflexThe arterial baroreflex counters a fall in arterial pressure within seconds to a minute by raising heart rate, contractility, arteriolar resistance and venous tone; the simulator implements it as an explicit first-order option with stated gains and time constant.
General · Any
TXT-physiology
TODO
Teaching approximation
Proposed
CL-force-intervalA premature beat is weaker and the beat after a compensatory pause is stronger (post-extrasystolic potentiation) with a longer filling time; in a normal heart aortic pulse pressure rises after the pause, in dynamic obstruction it falls.
General · Any
S04, TXT-physiology
TODO
Clinical reference
Proposed
CL-exercise-hemodynamicsExercise raises heart rate, contractility and venous return and lowers systemic resistance; the slope of mean PA pressure (and PAWP) against cardiac output during exercise carries information beyond resting values, with published thresholds depending on protocol and population.
General · Any
S05, TXT-physiology
TODO: exercise hemodynamics literature
Clinical reference
Proposed
CL-mcs-flow-accountingUnder mechanical support, flows that enter the systemic arteries in parallel (native aortic ejection, a microaxial pump from the LV, an ECMO return) add to total systemic output; flows through serial segments of one circuit must not be added. Native and device contributions should be displayed separately.
General · Any
S09
TODO
Clinical reference
Proposed
CL-shunt-oxygenA left-to-right intracardiac shunt raises the oxygen saturation of the chamber it enters (step-up) and makes pulmonary flow exceed systemic flow; Qp/Qs is derived from the saturations at the systemic arterial, mixed venous and pulmonary arterial sites.
General · Any
S07, TXT-physiology
TODO
Clinical reference
Proposed
CL-iabp-timingCounterpulsation inflates at aortic valve closure (dicrotic notch) and deflates just before ejection; early inflation and late deflation raise LV afterload, late inflation and early deflation lose augmentation and unloading. Counterpulsation is not a continuous addition of cardiac output.
General · Any
S09
TODO
Clinical reference
Proposed
CL-va-ecmo-lvPeripheral VA-ECMO returns blood retrograde into the arterial tree, raising LV afterload; a weak LV may fail to open the aortic valve, distend and raise pulmonary pressures, which is the rationale for LV venting or unloading (e.g. ECPELLA). Favourable unloading does not by itself establish survival benefit or device preference.
General · Any
S09
TODO
Clinical reference
Proposed
CL-impella-performanceMicroaxial pump flow depends on the pressure head between aorta and LV and on the speed setting; the nominal maximum is not delivered at every head, and inadequate LV filling causes suction.
General · Any
S09
TODO: manufacturer performance curves required per model
Clinical reference
Proposed
CL-structural-remodellingRelief of a valve lesion changes loading immediately; chamber remodelling follows over months. Removing a regurgitant outlet can unmask afterload mismatch in a dilated ventricle, so the immediate response is case specific.
General · Any
S03
TODO
Clinical reference
Proposed

Sources